AC 200A/600A, AC 200V/600V(RMS)
|
| Á¦Á¶»ç |
: YOKOGAWA |
| Á¦Ç°¸í |
: CLAMP METERS |
| Á¦Ç°¹øÈ£ |
: CL135 |
| Á¦Ç°ºÐ·ù |
: Ŭ·¥ÇÁ¹ÌÅÍ |
|
|
|
|
| |
|
|
|
|
|
 |
|
¡Ü TRUE RMS DISPLAY
¡Ü DATA HOLD FUNCTION
¡Ü APPROVED FOR COMFORMITY TO SAFETY STANDARD EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V)
|
|
|
 |
|
Specifications
| Display (LCD, Digital Counts) |
1999 |
| AC Current Accuracy (200A Reference) |
1.54(50/60Hz) 2.05(40~1kHz) |
| AC Current Accuracy (600A Reference) |
1.54(50/60Hz) 2.05(40~1kHz) |
| AC Voltage Accuracy (200V/600V Reference) |
1.02(50/60Hz) 1.54(40~1kHz) |
| Crest Factor |
(50/60Hz) |
| Resistance Accuracy (200&Omega reference) |
1.24, Beeps at below 30&Omega (continuity check) |
| Method of detection |
True RMS |
| Response Time |
Approx. 1 seconds (approx. 2 seconds on resistance range) |
| Range Switching |
Manual-range |
| Data hold |
On all range |
| Operating temperature and humidity |
-10-50°C. (no condensation) up to 30°C, 90% RH up to 40°C, 75% RH up to 50°C, 45% RH |
| Influence of external magnetic field |
2A or less at 400A/m |
| Influence of conductor position |
± 3% or less |
| Safety Standard |
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
| Circuit voltage |
600Vrms or less |
| Withstanding voltage |
5.55kV AC for one minute |
| Power Supply |
6F22(006P)9Vx1 or 6LR61x2 |
| Battery Life1 |
100 hours |
| Consumed current |
Approx. 2mA |
| Auto power-off |
Approx. 10 minutes |
| Diameter of measurable conductor |
30mm at maximum |
| Dimensions |
Approx. 93(W)x210(H)x40(D)mm |
| Weight (Approx.) |
400g |
| Accessories |
Clamp Adapter (Model 99025), Carrying Case (Model 93032), Test Lead (Model 98010), User''s manual (IM CL120), batteries |
| Order Notes |
Each item selected MUST be ordered as a separate line item. |
| Product Notes |
All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |
1 Approximate, continuous
Selection Guide
| AC Current Range |
200/600A |
| AC Current Resolution |
0.1A |
| AC Current Frequency characteristics |
40~1kHz |
| AC Current Method of detection |
True RMS |
| AC Voltage Measurement |
O |
| DC Voltage Measurement |
- |
| Continuity Check Measurement |
O |
| Frequency Measurement |
- |
| Temperature Measurement |
- |
| Recorder output Function |
- |
| Waveform monitor output Function |
- |
| Data hold Function |
O |
| Auto hold Function |
- |
| Peak Hold Function |
- |
| Maximum value memory Function |
- |
| Mean value display Function |
- |
| Filter Function |
- |
| Range Hold Function |
O |
| Auto ZERO Adjust Function |
- |
| Auto power-off Function |
- |
|
|
|
|
| |
| |
|
| |
|