AC 400/1500/2000A, AC 40/400/750V, DC 40/400/1000V, DC OUTPUT ±â´É
|
| Á¦Á¶»ç |
: YOKOGAWA |
| Á¦Ç°¸í |
: CLAMP METERS |
| Á¦Ç°¹øÈ£ |
: CL150 |
| Á¦Ç°ºÐ·ù |
: Ŭ·¥ÇÁ¹ÌÅÍ |
|
|
|
|
| |
|
|
|
|
|
 |
|
¡Ü MEAN VALUE DISPLAY
¡Ü DC OUTPUT FUNCTION
¡Ü DATA HOLD FUNCTION
¡Ü SLEEP FUNCTION
¡Ü APPROVED FOR COMFORMITY TO SAFETY STANDARDS EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)
|
|
|
 |
|
Specifications
| Display (LCD, Digital Counts) |
3999 |
| AC Current Accuracy (400A Reference) |
1.03(50/60Hz) 2.03(40~1kHz) |
| AC Current Accuracy (2000A Reference, 0~1500A) |
1.03(50/60Hz) 3.03(40~1kHz) |
| AC Voltage Accuracy (40/400V/750V Reference) |
1.02(50/60Hz) 1.53(40~1kHz) |
| DC Voltage Accuracy (40/400V/1000V Reference) |
1.02 |
| Resistance Accuracy (400/4k/40k/400k&Omega reference) |
1.52, Beeps at below 50± 35&Omega (continuity check) |
| DC Output Accuracy (400A, 0~400mV Reference) |
.5?% rdg ± 0.5mV (50/60Hz) .5% rdg ± 0.5mV (40~1kHz) |
| Method of detection |
Mean Value |
| Response Time |
Approx. 2 seconds |
| Range Switching |
Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range) |
| Data hold |
On all range |
| Operating temperature and humidity |
0-40°C, 85% RH or less (no condensation) |
| Influence of external magnetic field |
1A or less at 400A/m |
| Influence of conductor position |
± (2% rdg 3dgt) or less |
| Safety Standard |
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
| Circuit voltage |
1000Vrms or less |
| Withstanding voltage |
5.55kV AC for one minute |
| Power Supply |
R6P(SUM-3)x2 or LR6x2 |
| Battery Life1 |
150 hours |
| Consumed current |
Approx. 5mA |
| Sleep Function |
Automatically powered down in about 10 minutes after the last switch operation |
| Diameter of measurable conductor |
54mm at maximum |
| Dimensions |
Approx. 105(W) x 247(H) x 49(D)mm |
| Weight (Approx.) |
470g |
| Accessories |
Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User''s manual (IM CL150), batteries |
| Order Notes |
Each item selected MUST be ordered as a separate line item. |
| Product Notes |
All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |
1 Approximate, continuous
Selection Guide
| AC Current Range |
400/2000A |
| AC Current Resolution |
0.1A |
| AC Current Frequency characteristics |
40~1kHz |
| AC Current Method of detection |
Mean Value |
| AC Voltage Measurement |
O |
| DC Voltage Measurement |
O |
| Continuity Check Measurement |
O |
| Frequency Measurement |
- |
| Temperature Measurement |
- |
| Recorder output Function |
O |
| Waveform monitor output Function |
- |
| Data hold Function |
O |
| Auto hold Function |
- |
| Peak Hold Function |
O |
| Maximum value memory Function |
- |
| Mean value display Function |
- |
| Filter Function |
- |
| Range Hold Function |
O (current range) |
| Auto ZERO Adjust Function |
- |
| Auto power-off Function |
O Sleep function (power-down) |
|
|
|
|
| |
| |
|
| |
|