AC 400/600A, DC 400/1000A, AC/DC 400V/600V (RMS)
|
| Á¦Á¶»ç |
: YOKOGAWA |
| Á¦Ç°¸í |
: CLAMP METERS |
| Á¦Ç°¹øÈ£ |
: CL235 |
| Á¦Ç°ºÐ·ù |
: Ŭ·¥ÇÁ¹ÌÅÍ |
|
|
|
|
| |
|
|
|
|
|
 |
|
¡Ü TRUE RMS DISPLAY
¡Ü SLEEP FUNCTION
¡Ü DATA HOLD FUNCTION
¡Ü APPROVED FOR COMFORMITY TO SAFETY STANDARDS EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V)
|
|
|
 |
|
Specifications
| Description |
True RMS ACA, ACV, DCA, DCV |
| Method of detection |
True RMS |
| Display |
LCD (Digital display: 3999 counts) |
| DC Current Range |
400/1000A |
| DC Current Resolution |
0.1A |
| Response Time |
Approx. 2 second |
| Range Switching |
Auto-range |
| Data hold |
On all range |
| Operating temperature and humidity |
0 - 40°C, 90% RH or less (no condensation) |
| Influence of conductor position |
±2% or less |
| Safety Standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
| Circuit voltage |
600 Vrms or less |
| Withstanding voltage |
5.55 kV AC for one minute |
| Power Supply |
6F22 (006P) 9V x 1 6LR61 x 1 |
| Battery Life |
Approx. 15 hours (continuous) |
| Consumed current |
Approx. 15 mA |
| Sleep Function |
Automatically powered down in about 30 minutes after the last switch operation |
| Diameter of measurable conductor |
33 mm at maximum |
| Dimensions |
Approx. 91 (W) x 210 (H) x 40 (D) mm |
| Weight |
Approx. 450 g |
| Accessories |
Batteries, carrying case (93032) User''s manual (IM CL235) |
| Peak Hold |
On AC/DC current range, AC/DC voltage range |
 
Selection Guide
| AC Current Range |
400/600A |
| AC Current Resolution |
0.1A |
| AC Current Frequency characteristics |
40~1kHz |
| AC Current Method of detection |
True RMS |
| AC Voltage Measurement |
O |
| DC Voltage Measurement |
O |
| Continuity Check Measurement |
O |
| Frequency Measurement |
O |
| Temperature Measurement |
- |
| Recorder output Function |
- |
| Waveform monitor output Function |
- |
| Data hold Function |
O |
| Auto hold Function |
- |
| Peak Hold Function |
O |
| Maximum value memory Function |
- |
| Mean value display Function |
O |
| Filter Function |
- |
| Range Hold Function |
- |
| Auto ZERO Adjust Function |
O |
| Auto power-off Function |
&Delta |
 
Additional Specification
At 23°C±5°C£¬75%RH or less Accuracy: ±( % rdg dgt) = ±(% readout value of least significant digit)
| Parameter | Reference | Accuracy |
| AC current |
400/600A |
1.55 (50/60Hz) |
| 3.55 (40¢¦1kHz) |
| DC current |
400/1000A |
1.05 |
| AC voltage |
40/400/600V |
1.55 (50/60Hz) |
| 3.55 (40¢¦1kHz) |
| DC voltage |
40/400/600V |
1.05 |
| Crest factor |
  |
?3 |
| Resistance |
400/4000&Omega |
1.05 , Beeps at below 20&Omega (continuity check) |
| Frequency |
10¢¦3000Hz |
1.55 |
|
|
|
|
| |
| |
|
| |
|