YOKOGAWA - - 73204
SPECIAL MODEL F VOLTAGE MEASUREMENT ±â´ÉžÀç
Á¦Á¶»ç : YOKOGAWA
Á¦Ç°¸í : DIGITAL MULTIMETER
Á¦Ç°¹øÈ£ : 73204
Á¦Ç°ºÐ·ù : µðÁöÅиÖƼ¹ÌÅÍ
Á¦Ç°»ó¼¼Á¤º¸
Display | 4300-count digital reading |
---|---|
DC Voltage Accuracy1 | 0.75% 1 |
AC Voltage Accuracy2 | 1% 5 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) Amend EN61010-2-031 (1995) (600 V, CAT II 300 V, CAT III contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range
2 4V - 600V Range
 
Specifications - Model 73202/R
Display | 4300-count digital reading |
---|---|
DC Voltage Accuracy1 | 0.5% 1 |
AC Voltage Accuracy2 | 1% 5 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) Amend EN61010-2-031 (1995) (600 V, CAT II 300 V, CAT III contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range
2 4V - 600V Range
 
Specifications - Model 73203/R
Display | 4300-count digital reading |
---|---|
DC Voltage Accuracy1 | 0.5% 1 |
AC Voltage Accuracy2 | 0.75% 1 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) Amend EN61010-2-031 (1995) (600 V, CAT II 300 V, CAT III contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range
2 4V - 600V Range
 
Specifications - Model 73204/R
Display | 4300-count digital reading |
---|---|
DC Voltage Accuracy1 | 0.3% 1 |
AC Voltage Accuracy2 | 0.75% 1 |
Additional Functions | Auto hold, overvoltage and current warning |
Features |
|
Operating Temp and Humidity | 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
Power Supply | Two AAA (LR03 or R03) dry cells |
Battery Life | Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
Dimensions | 74 (W) x 155 (H) x 31 (D) mm |
Weight | Approx. 240 g (including batteries) |
Compliance with Standards | Safety EN61010-1 (1995) Amend EN61010-2-031 (1995) (600 V, CAT II 300 V, CAT III contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
Standard Accessories | AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
Optional Accessories | Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range
2 4V - 600V Range
Model Numbers
Model | Description |
---|---|
73201/R | Display 4300-count digital reading DC Voltage Accuracy 0.75% 1 AC Voltage Accuracy 1% 5 |
73203/R | Display 4300-count digital reading DC Voltage Accuracy 0.5% 1 AC Voltage Accuracy 0.75% 1 |
73202/R | Display 4300-count digital reading DC Voltage Accuracy 0.5% 1 AC Voltage Accuracy 1% 5 |
73204/R | Display 4300-count digital reading DC Voltage Accuracy 0.3% 1 AC Voltage Accuracy 0.75% 1 |
Á¦Ç°Á¤º¸
¡Ü SPECIAL MODEL F VOLTAGE MEASUREMENT
¡Ü ACCURACY 0.5% AT DC VOLTAGE 4300 COUNT DIGITAL DISPLAY
¡Ü COMPACT SIZE & IDEAL F CARRYING
¡Ü LARGE DISPLAY F EASY VIEWING
¡Ü AUTO HOLD FUNCTION
¡Ü 3 YEAR WARRANTY