·¹ÄÚ´õ(¿Âµµ±â·Ï°è)
  µ¥ÀÌÅͷΰÅ
  Àü·Â(ºÐ¼®)°è
  ½ºÄÚÇÁÄÚ´õ
  ¿À½Ç·Î½ºÄÚÇÁ
  °¡½º °¨Áö±â
  ³»Àü¾Ð/¾ÈÀü±Ô°Ý
  ´©¼³Àü·ù°è
  µðÁöÅиÖƼ¹ÌÅÍ
  ¸Þ¸ð¸® ÇÏÀÌÄÚ´õ
  ½ÅÈ£¹ß»ý±â
  ¿­È­»óÄ«¸Þ¶ó
  ¿Âµµ°è
  Àڿܼ±Ä«¸Þ¶ó
  ÀúÀúÇ×°è/¹èÅ͸®Å×½ºÅÍ
  Àý¿¬ÀúÇ×°è
  Á¢ÁöÀúÇ×°è
  Á¶µµ°è/ȸÀü°è
  Ãæ°Ý±â·Ï°è(Impact ...
  Ä¶¸®ºê·¹ÀÌÅÍ
  Å¬·¥ÇÁ¹ÌÅÍ
  AC Calibrator
  Power Supply

YOKOGAWA - - 73201

ACCURACH 0.5 % AT DC VOLTAGE AND 4300 COUNT DIGITAL DISPLAY

Á¦Á¶»ç : YOKOGAWA

Á¦Ç°¸í : DIGITAL MULTIMETER

Á¦Ç°¹øÈ£ : 73201

Á¦Ç°ºÐ·ù : µðÁöÅиÖƼ¹ÌÅÍ

Á¦Ç°Á¤º¸

  • ¡Ü ACCURACH 0.5 % AT DC VOLTAGE AND 4300 COUNT DIGITAL DISPLAY
    ¡Ü COMPACT SIZE & IDEAL FOR CARRYING
    ¡Ü LARGE DISPLAY FOR EASY VIEWING
    ¡Ü SAFE DESIGN ALLOWS MEASURMENT IN EXCESS OF 20A
    ¡Ü AUTO HOLD FUNCTION
    ¡Ü 3 YEAR WARRANTY

Á¦Ç°»ó¼¼Á¤º¸


Specifications - Model 73201/R

Display 4300-count digital reading
DC Voltage Accuracy1 0.75% 1
AC Voltage Accuracy2 1% 5
Additional Functions Auto hold, overvoltage and current warning
Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
  • Operating Temp and Humidity 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
    Power Supply Two AAA (LR03 or R03) dry cells
    Battery Life Approx. 600 hours (for continuous DC voltage measurement with alkaline cells)
    Dimensions 74 (W) x 155 (H) x 31 (D) mm
    Weight Approx. 240 g (including batteries)
    Compliance with Standards Safety EN61010-1 (1995) Amend
    EN61010-2-031 (1995) (600 V, CAT II 300 V, CAT III
    contamination level 2, indoor use: 73201,73202, 73203)
    EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
    Standard Accessories AAA (LR03/R03) dry cells (built in): 2
    Instruction manual: 1
    Spare fuse F02 (15 A/250 V): 1
    Spare fuse F05 (500 mA/250 V): 1
    Test lead set (RD031) :1
    Optional Accessories Carrying Case (hard) Hoses the DMM and test leads (B9648GB)
    Rubber Case for DMM (93007)

    1 40V - 600V Range
    2 4V - 600V Range

     

    Specifications - Model 73202/R

    Display 4300-count digital reading
    DC Voltage Accuracy1 0.5% 1
    AC Voltage Accuracy2 1% 5
    Additional Functions Auto hold, overvoltage and current warning
    Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
  • Operating Temp and Humidity 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
    Power Supply Two AAA (LR03 or R03) dry cells
    Battery Life Approx. 600 hours (for continuous DC voltage measurement with alkaline cells)
    Dimensions 74 (W) x 155 (H) x 31 (D) mm
    Weight Approx. 240 g (including batteries)
    Compliance with Standards Safety EN61010-1 (1995) Amend
    EN61010-2-031 (1995) (600 V, CAT II 300 V, CAT III
    contamination level 2, indoor use: 73201,73202, 73203)
    EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
    Standard Accessories AAA (LR03/R03) dry cells (built in): 2
    Instruction manual: 1
    Spare fuse F02 (15 A/250 V): 1
    Spare fuse F05 (500 mA/250 V): 1
    Test lead set (RD031) :1
    Optional Accessories Carrying Case (hard) Hoses the DMM and test leads (B9648GB)
    Rubber Case for DMM (93007)

    1 40V - 600V Range
    2 4V - 600V Range

     

    Specifications - Model 73203/R

    Display 4300-count digital reading
    DC Voltage Accuracy1 0.5% 1
    AC Voltage Accuracy2 0.75% 1
    Additional Functions Auto hold, overvoltage and current warning
    Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
  • Operating Temp and Humidity 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
    Power Supply Two AAA (LR03 or R03) dry cells
    Battery Life Approx. 600 hours (for continuous DC voltage measurement with alkaline cells)
    Dimensions 74 (W) x 155 (H) x 31 (D) mm
    Weight Approx. 240 g (including batteries)
    Compliance with Standards Safety EN61010-1 (1995) Amend
    EN61010-2-031 (1995) (600 V, CAT II 300 V, CAT III
    contamination level 2, indoor use: 73201,73202, 73203)
    EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
    Standard Accessories AAA (LR03/R03) dry cells (built in): 2
    Instruction manual: 1
    Spare fuse F02 (15 A/250 V): 1
    Spare fuse F05 (500 mA/250 V): 1
    Test lead set (RD031) :1
    Optional Accessories Carrying Case (hard) Hoses the DMM and test leads (B9648GB)
    Rubber Case for DMM (93007)

    1 40V - 600V Range
    2 4V - 600V Range

     

    Specifications - Model 73204/R

    Display 4300-count digital reading
    DC Voltage Accuracy1 0.3% 1
    AC Voltage Accuracy2 0.75% 1
    Additional Functions Auto hold, overvoltage and current warning
    Features
  • Accuracy 0.5% at DC voltage and 4300 count digital Display
  • Compact size & ideal for carrying
  • Large display for easy viewing
  • Safe design allows measurement in excess of 20A
  • Auto hold function
  • 3 year warranty
  • Operating Temp and Humidity 0 to 50°C 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation)
    Power Supply Two AAA (LR03 or R03) dry cells
    Battery Life Approx. 600 hours (for continuous DC voltage measurement with alkaline cells)
    Dimensions 74 (W) x 155 (H) x 31 (D) mm
    Weight Approx. 240 g (including batteries)
    Compliance with Standards Safety EN61010-1 (1995) Amend
    EN61010-2-031 (1995) (600 V, CAT II
    300 V, CAT III contamination level 2, indoor use: 73201,73202, 73203)
    EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997)
    Standard Accessories AAA (LR03/R03) dry cells (built in): 2
    Instruction manual: 1
    Spare fuse F02 (15 A/250 V): 1
    Spare fuse F05 (500 mA/250 V): 1
    Test lead set (RD031) :1
    Optional Accessories Carrying Case (hard) Hoses the DMM and test leads (B9648GB)
    Rubber Case for DMM (93007)

    1 40V - 600V Range
    2 4V - 600V Range

    Model Description
    73201/R Display 4300-count digital reading DC Voltage Accuracy 0.75% 1 AC Voltage Accuracy 1% 5
    73203/R Display 4300-count digital reading DC Voltage Accuracy 0.5% 1 AC Voltage Accuracy 0.75% 1
    73202/R Display 4300-count digital reading DC Voltage Accuracy 0.5% 1 AC Voltage Accuracy 1% 5
    73204/R Display 4300-count digital reading DC Voltage Accuracy 0.3% 1 AC Voltage Accuracy 0.75% 1