- - CL150
AC 400/1500/2000A, AC 40/400/750V, DC 40/400/1000V, DC OUTPUT ±â´É
Á¦Á¶»ç : YOKOGAWA
Á¦Ç°¸í : CLAMP METERS
Á¦Ç°¹øÈ£ : CL150
Á¦Ç°ºÐ·ù : Ŭ·¥ÇÁ¹ÌÅÍ
Á¦Ç°»ó¼¼Á¤º¸
| Display (LCD, Digital Counts) | 3999 |
|---|---|
| AC Current Accuracy (400A Reference) | 1.03(50/60Hz) 2.03(40~1kHz) |
| AC Current Accuracy (2000A Reference, 0~1500A) | 1.03(50/60Hz) 3.03(40~1kHz) |
| AC Voltage Accuracy (40/400V/750V Reference) | 1.02(50/60Hz) 1.53(40~1kHz) |
| DC Voltage Accuracy (40/400V/1000V Reference) | 1.02 |
| Resistance Accuracy (400/4k/40k/400k&Omega reference) | 1.52, Beeps at below 50± 35&Omega (continuity check) |
| DC Output Accuracy (400A, 0~400mV Reference) | .5?% rdg ± 0.5mV (50/60Hz) .5% rdg ± 0.5mV (40~1kHz) |
| Method of detection | Mean Value |
| Response Time | Approx. 2 seconds |
| Range Switching | Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range) |
| Data hold | On all range |
| Operating temperature and humidity | 0-40°C, 85% RH or less (no condensation) |
| Influence of external magnetic field | 1A or less at 400A/m |
| Influence of conductor position | ± (2% rdg 3dgt) or less |
| Safety Standard | Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
| Circuit voltage | 1000Vrms or less |
| Withstanding voltage | 5.55kV AC for one minute |
| Power Supply | R6P(SUM-3)x2 or LR6x2 |
| Battery Life1 | 150 hours |
| Consumed current | Approx. 5mA |
| Sleep Function | Automatically powered down in about 10 minutes after the last switch operation |
| Diameter of measurable conductor | 54mm at maximum |
| Dimensions | Approx. 105(W) x 247(H) x 49(D)mm |
| Weight (Approx.) | 470g |
| Accessories | Clamp Adapter (Model 99025), Output Cable for Terminal Screw (Model 91019), Carrying Case (Model 93034), Output Plug (Model 98012), Test Lead (Model 98011), User''s manual (IM CL150), batteries |
| Order Notes | Each item selected MUST be ordered as a separate line item. |
| Product Notes | All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |
1 Approximate, continuous
Selection Guide
| AC Current Range | 400/2000A |
|---|---|
| AC Current Resolution | 0.1A |
| AC Current Frequency characteristics | 40~1kHz |
| AC Current Method of detection | Mean Value |
| AC Voltage Measurement | O |
| DC Voltage Measurement | O |
| Continuity Check Measurement | O |
| Frequency Measurement | - |
| Temperature Measurement | - |
| Recorder output Function | O |
| Waveform monitor output Function | - |
| Data hold Function | O |
| Auto hold Function | - |
| Peak Hold Function | O |
| Maximum value memory Function | - |
| Mean value display Function | - |
| Filter Function | - |
| Range Hold Function | O (current range) |
| Auto ZERO Adjust Function | - |
| Auto power-off Function | O Sleep function (power-down) |


Á¦Ç°Á¤º¸
¡Ü MEAN VALUE DISPLAY
¡Ü DC OUTPUT FUNCTION
¡Ü DATA HOLD FUNCTION
¡Ü SLEEP FUNCTION
¡Ü APPROVED FOR COMFORMITY TO SAFETY STANDARDS EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)