- - CL250
AC/DC 400/2000A, AC 400/750V, DC 400/1000V (DC OUTPUT±â´É)
Á¦Á¶»ç : YOKOGAWA
Á¦Ç°¸í : CLAMP METERS
Á¦Ç°¹øÈ£ : CL250
Á¦Ç°ºÐ·ù : Ŭ·¥ÇÁ¹ÌÅÍ
Á¦Ç°»ó¼¼Á¤º¸
| Description | ACA, DCA, ACV, DCV, OHM, Freq. °C Continuity Check |
|---|---|
| Method of detection | Mean Value |
| Display | LCD (Digital display: 3999 counts) |
| DC Current Range | 400/2000A |
| DC Current Resolution | 0.1A |
| Response Time | Approx. 2 seconds |
| Range Switching | Auto-range (on resistance range) Manual-range (on current, voltage range) |
| Operating temperature and humidity | 0 - 40°C, 85% RH or less (no condensation) |
| Influence of external magnetic field | 4A or less at 400 A/m |
| Influence of conductor position | ±(1.5% rdg 3 dgt) or less |
| Safety Standard | Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
| Circuit voltage | 1000 Vrms or less |
| Withstanding voltage | 5.55 kV AC for one minute |
| Power Supply | LR6 x 2 R6P (SUM-3) x 2 |
| Battery Life | Approx. 100 hours (continuous) |
| Consumed current | Approx. 9 mA |
| Sleep Function | Automatically powered down in about 10 minutes after the last switch operation |
| Diameter of measurable conductor | 55 mm at maximum |
| Dimensions | Approx. 105 (W) x 250 (H) x 49 (D) mm |
| Weight | Approx. 530 g |
| Accessories | Batteries, carrying case (93034) Output plug (98012) Test Lead (98011) User''s manual (IM CL250) |
| Peak Hold | On all range |
| Max Hold | On current / Voltage range |
 
Selection Guide
| AC Current Range | 400/2000A |
|---|---|
| AC Current Resolution | 0.1A |
| AC Current Frequency characteristics | 40~1kHz |
| AC Current Method of detection | Mean Value |
| AC Voltage Measurement | O |
| DC Voltage Measurement | O |
| Continuity Check Measurement | O |
| Frequency Measurement | - |
| Temperature Measurement | - |
| Recorder output Function | O |
| Waveform monitor output Function | - |
| Data hold Function | O |
| Auto hold Function | - |
| Peak Hold Function | - |
| Maximum value memory Function | O |
| Mean value display Function | - |
| Filter Function | - |
| Range Hold Function | (current range) |
| Auto ZERO Adjust Function | O |
| Auto power-off Function | &Delta |
 
Additional Specification
At 23°C±5°C£¬75%RH or less
Accuracy: ±( % rdg dgt) = ±(% readout value of least significant digit)
| Parameter | Reference | Accuracy |
|---|---|---|
| DC current | 400/2000A | 1.52 |
| AC current | 400A/2000A(0¢¦1000A) | 1.52 (50/60Hz) |
| 3.04 (40¢¦500Hz) | ||
| 5.04 (500¢¦1kHz) | ||
| 2000A (1001¢¦2000A) | 3.02 (50/60Hz) | |
| DC voltage | 400/1000V | 1.02 |
| AC voltage | 400/750V | 1.52 (50/60Hz) |
| 1.54 (40¢¦1kHz) | ||
| Resistance | 400/4000&Omega | 1.52 , Beeps at below 50±35&Omega (continuity check) |
| DC output | DC400A (0¢¦400mV) | ±1.5% rdg ±3mV |
| DC2000A (0¢¦200mV) | ±1.5% rdg ±3mV | |
| AC400A (0¢¦400mV) AC2000A (0¢¦100mV/0¢¦1000A) | ±1.5% rdg ±3mV (50/60Hz) | |
| ±3.0% rdg ±3mV (40¢¦500Hz) | ||
| ±5.0% rdg ±3mV (500¢¦1kHz) | ||
| AC2000A (100.1¢¦200mV/1001¢¦2000A) | ±3.0% rdg ±3mV (50/60Hz) |


Á¦Ç°Á¤º¸
¡Ü MEAN VALUE DISPLAY
¡Ü SLEEP FUNCTION
¡Ü DATA HOLD FUNCTION
¡Ü APPROVED FOR COMFORMITY TO SAFETY STANDARDS EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)