YOKOGAWA - - MW100
»ç¿ëÀÚÀÇ ÆíÀǼºÀ» °âºñÇÏ°í °í¼º´É,Ź¿ùÇÑ µ¥ÀÌÅÍ Ã³¸®´É·ÂÀ» °¡Áø Â÷¼¼´ë PCº£À̽º µ¥ÀÌÅÍ ¼öÁýÀåºñ
Á¦Á¶»ç : YOKOGAWA
Á¦Ç°¸í : DAQMASTER
Á¦Ç°¹øÈ£ : MW100
Á¦Ç°ºÐ·ù : ·¹ÄÚ´õ(¿Âµµ±â·Ï°è)
Á¦Ç°»ó¼¼Á¤º¸
´Ù¾çÇÑ Æ¯Â¡
|
º»Ã¼»ç¾ç |
SYSTEM CONFIGURATION |
¡Ü STANDARD CONFIGURATION
|
INPUT MODULES
|
NAME
|
MODEL
|
NUMBER OF CHANNELS
|
SHORTEST MEASUREMENT INTERVAL
|
DESCRIPTION
|
UNIVERSAL INPUT MODULES | MX110-UNV-H04 | 4 | 10 MS | DC VOLTAGE, THERMOCOUPLE, 3-WIRE RTD, DI (NON-VOLTAGE CONTACT, LEVEL (5 V LOGIC)). MIXED INPUT ALLOWED. |
MX110-UNV-M10 | 10 | 100 MS | DC VOLTAGE, THERMOCOUPLE, 3-WIRE RTD, DI (NON-VOLTAGE CONTACT, LEVEL (5 V LOGIC)). MIXED INPUT ALLOWED. | |
4-WIRE RTD AND RESISTANCE INPUT MODULE | MX110-V4R-M06 | 6 | 100 MS | DC VOLTAGE, 4-WIRE RTD, 4-WIRE RESISTANCE, DI (NON-VOLTAGE CONTACT, LEVEL (5 V LOGIC)). MIXED INPUT ALLOWED. |
STRAIN INPUT MODULES | MX112-B12-M04 | 4 | 100 MS | BUILT-IN BRIDGE RESISTANCE OF 120 OHM |
MX112-B35-M04 | BUILT-IN BRIDGE RESISTANCE OF 350 OHM | |||
MX112-NDI-M04 | FOR CONNECTION WITH AN EXTERNAL BRIDGE HEAD AND STRAIN GAUGE TYPE SENSOR (NDIS CONNECTOR)) | |||
5 V DIGITAL INPUT MODULE | MX115-D05-H10 | 10 | 10 MS | NON-VOLTAGE CONTACT, OPEN COLLECTOR, AND LEVEL (5 V LOGIC). MIXED INPUT ALLOWED. |
24 V DIGITAL INPUT MODULE | MX115-D24-H10 | 10 | 10 MS | LEVEL (24 V LOGIC), VTH = 12 V |
OUTPUT MODULES
|
NAME
|
MODEL
|
NUMBER OF CHANNELS
|
SHORTEST MEASUREMENT INTERVAL
|
DESCRIPTION
|
ANALOG OUTPUT MODULE | MX120-VAO-M08 | 8 | 100 MS | ALLOWS MIXED VOLTAGE (¡¾10 V) AND CURRENT (4-20 MA) OUTPUT |
PWM OUTPUT MODULE | MX120-PWM-M08 | 8 | 100 MS | PULSE WIDTH MODULATION OUTPUT MODULE |
DIGITAL OUTPUT MODULE | MX125-MKC-M10 | 10 | 100 MS | ¡°A¡± CONTACT (SPST) |
BASE PLATE | |
BASE PLATES AVAILABLE FOR ALL CONFIGURATIONS, FROM 1 TO 6 INPUT/OUTPUT MODULES. WHEN USED FOR THE MW100, YOU MUST REPLACE THE ATTACHMENT WITH THE ONE THAT COMES STANDARD WITH THE MW100. |
ACCESSORIES | |
CONNECTOR COVERS CONNECTOR COVERS FOR OPEN SLOTS | |
AC ADAPTER (772075) AC ADAPTER FOR THE DC POWER MODEL. OPERATING TEMPERATURE RANGE: 0 TO 40¡Æ |
ACCESSORIES (REMOVABLE TERMINAL) | |
ALL INPUT/OUTPUT TERMINALS ARE REMOVABLE EXCEPT FOR THOSE OF THE MX112-NDI-M04. IF MULTIPLE TERMINALS ARE PREPARED AHEAD OF TIME, NO RE-WIRING IS NEEDED BETWEEN MEASUREMENTS. |
RECORDING CHANNELS
|
MEASUREMENT INTERVAL
|
128 M
|
512 M
|
1 G
|
10 CH
|
10 MS 1
|
APPROX. 8.8 HOURS | APPROX. 1.4 DAYS | APPROX. 2.8 DAYS |
100 MS
|
APPROX. 3.7 DAYS | APPROX. 14.8 DAYS | APPROX. 28.9 DAYS | |
500 MS
|
APPROX. 18.5 DAYS | APPROX. 74.0 DAYS | APPROX. 144 DAYS | |
1 S
|
APPROX. 37.0 DAYS | APPROX. 148 DAYS | APPROX. 289 DAYS | |
2 S
|
APPROX. 74.0 DAYS | APPROX. 296 DAYS | APPROX. 578 DAYS (APPROX. 1.5 YEARS) | |
5 S
|
APPROX. 185 DAYS | APPROX. 740 DAYS | APPROX. 1446 DAYS (APPROX. 3.9 YEARS) | |
20 CH
|
5 S
|
APPROX. 185 DAYS | APPROX. 740 DAYS | APPROX. 1446 DAYS (APPROX. 3.9 YEARS) |
100 MS
|
APPROX. 1.8 DAYS | APPROX. 7.4 DAYS | APPROX. 14.4 DAYS | |
500 MS
|
APPROX. 9.2 DAYS | APPROX. 37.0 DAYS | APPROX. 72.3 DAYS | |
1 S
|
APPROX. 18.5 DAYS | APPROX. 74.0 DAYS | APPROX. 144 DAYS | |
2 S
|
APPROX. 37.0 DAYS | APPROX. 148 DAYS | APPROX. 289 DAYS | |
5 S
|
APPROX. 92.5 DAYS | APPROX. 370 DAYS (APPROX. 1 YEAR) | APPROX. 723 DAYS (APPROX. 1.9 YEARS) | |
60 CH
|
100 MS
|
APPROX. 14.8 HOURS | APPROX. 2.4 DAYS | APPROX. 4.8 DAYS |
500 MS
|
APPROX. 3.0 DAYS | APPROX. 12.3 DAYS | APPROX. 24.1 DAYS | |
1 S
|
APPROX. 6.1 DAYS | APPROX. 24.6 DAYS | APPROX. 48.2 DAYS | |
2 S
|
APPROX. 12.3 DAYS | APPROX. 49.3 DAYS | APPROX. 96.4 DAYS | |
5 S
|
APPROX. 30.8 DAYS | APPROX. 123 DAYS | APPROX. 241 DAYS | |
STORAGE CAPACITY IN TERMS OF TIME BY CF CARD SIZE AND NUMBERS OF CHANNELS |
Á¦Ç°Á¤º¸
¡Ü FEATURES AND BENEFITS
- °í¼Ó,´Ùä³Î,°í³»¾Ð
(HIGH-SPEED, MULTI-CHANNEL CAPABILITY, HIGH WITHSTAND VOLTAGE)
- °í¼Ó,´Ùä³Î,°í³»¾Ð
(HIGH-SPEED, MULTI-CHANNEL CAPABILITY, HIGH WITHSTAND VOLTAGE)
- ¸ÖƼÀÎÅ͹úÃøÁ¤
(MULTI-INTERVAL MEASUREMENT)
½Ã½ºÅÛ±¸¼ºÀÇ ¿ëÀÌ
(FLEXIBLE SYSTEM CONFIGURATION)
- ´Ù¾çÇÑ PCȯ°æ¿¡ ´ëÀÀ
(VERSATILE PC-BASED SOFTWARE OPTIONS)
- ½¬¿î ¼ÒÇÁÆ®¿þ¾î ¼Â¾÷
(EASY SOFTWARE SETUP)
- ¸ÅÃøÁ¤½Ã Àç¹è¼± ºÒÇÊ¿ä
(NO RE-WIRING BETWEEN MEASUREMENTS)